Suitable for L-type, U-type terminal & wire type AC capacitors with PP can of max 060mm and 300mm length including wire. Testing capacitor is to be loaded manually, Job will be transferred to the next station, low voltage I OOV AC, 10 A, will be applied in station 2. HV test done in the station3, Discharge through resistor will be done in station 4, direct discharge done at station 5, value and tan-d measurement will be done in station 6. Good capacitor will be sorted in sorted in station 7, Reject capacitor will sorted in station 8.